Compound detectors
Built-in detector for battery packs, combining smoke, temperature and CO sensing with optional VOC detection. CAN communication and multi-signal correlation support early warning.
Technical Specifications
Item
Specification
Nominal Voltage
24 V DC
Operating Voltage
18–32 V DC
Standby Current
≤8 mA; with VOCs ≤25 mA
Alarm Current
≤10 mA; with VOCs ≤27 mA
Operating Temperature
−40 to +60 °C
Operating Humidity
5–95% RH
Operating Air Pressure
70–110 kPa
Maximum Altitude
3,000 m
Smoke Detection
0–1 dB/m; resolution 0.02 dB/m
Temperature Detection
−40 to +120 °C; resolution 1 °C; accuracy ±2 °C
CO Detection
0–2,000 ppm; resolution 1 ppm; ±15% (−10 to +50 °C), ±30% otherwise
VOC Detection
Optional
Service Life
≥10 years
Wiring
4-wire (Power +/−, CAN_H/CAN_L)
Addressing
Electronic, 1–200
Indicator LEDs
Red, yellow and green
Explosion Protection Marking
Ex ib IIC T6 Gb